Liquid Propane Gas(LPG) Conversion
Gas Packing-1
Valve Adaptor
Gas Valve
Flange
Connector
Bracket
Gas Valve
Packing
Replace NG Valve Adaptor With LPG Adaptor
Gas Packing-2
Gas Packing-3
Loosen and remove 5 screws securing the Gas Valve Flange. Remove the Gas Valve Flange, Packing and
Valve Adaptor(NG). Replace Valve Adaptor(NG) with Valve Adaptor(LP). Reverse the steps above by reassem-
bling the packing, Gas Flange and Connector Bracket. Make sure all screws and secure and tightened.
Change Dip Switch No.8 position from left to right.
6.
7.
Reassemble Water Heater Casing
8 .Attach Top Panel and back on frame of the water heater and tighten the 2 screws. Attach Exhaust Top on Top
Panel and tighten the 4 screws. Attach Control Panel Assembly to frame and tighten the 2 screws on the
bottom of the panel. Remove The NG Label. Stick LPG label on the Panel.
PROPANE GAS
876